Siemens Skyra
The Siemens MAGNETOM Skyra is a 3 Tesla (3T) MRI scanner with a 70 cm open bore design and a magnet length of 163 cm. It utilizes Tim 4G coil technology with up to 204 coil elements and 128 independent RF channels. The system weight is 7.3 tons, and the minimum room size required is 31 m².
Here's a more detailed breakdown of the specifications:
Magnet System:
Coil Technology:
Other Specifications:
Siemens lumina 3t
The MAGNETOM Lumina is a 3T MRI system from Siemens Healthineers featuring a wide 70 cm open bore and the BioMatrix platform for patient personalization. Designed for high-volume environments, the Lumina incorporates technologies like Select&GO (for landmark-free patient positioning), syngo MR XA software, and Turbo Suite acceleration to streamline exams and reduce scan times by up to 50% without compromising image quality. AI-assisted Deep Resolve reconstruction uses neural networks to speed up imaging while maintaining diagnostic integrity. Workflow automation is further supported by GO technologies, BioMatrix Tuners, and myExam Assist protocols, enabling consistent and reproducible results across multiple scan types and body regions. With the syngo Virtual Cockpit, remote exam support is possible, making the Lumina well-suited for facilities aiming to improve throughput, diagnostic consistency, and overall patient experience.
Technical Specifications
Side by side:
Feature |
Siemens Lumina |
Siemens Skyra |
Field strength |
3 Tesla |
3 Tesla |
Bore size |
70 cm Open Bore design |
70 cm Open Bore |
Helium consumption |
Zero Helium boil-off technology |
Zero boil off technology |
Gradient strength |
XK gradients 36/200 simultaneously [1.7 MVA] |
XQ Gradients: 45 mT/m @ 200 T/m/s. |
Maximum number of channels4 |
180 |
Up to 204 coil elements with up to 128 independent RF channels. |
Number of independent receiver channels that can be used |
32 |
204x48, 204x64, 204x128 |
Power consumption |
Eco-Power technology |
84 kVA |
System length from cover to cover |
1.86 m |
1.73 m |
System weight (in operation) |
7.35 tons |
7.3 tons |
Minimum room size5 |
31 m² |
31 m2 |
Maximum effective slew rate |
NA |
346 T/m/s |